Mobile navigation
Fan selection software
Theoretical operating point
Q
m3/h
Δp
Pa
Categories
Search for fans
HFD EX - ATEX fan

HFD EX

ATEX fan

Chemically resistant fan
Contact us

Application

The fan is designed to transport dust-free medium containing aggressive chemical compounds. Typical fields of application:

  • fume cupboards and chemical laboratories
  • chemical, pharmaceutical and food industries
  • public utility facilities

Construction

  • rotor molded from PPs plastic,
  • housing made of PEs plastic,
  • stainless fasteners,
  • installation in vertical or horizontal position,
  • maximum temperature of the pumped medium 40°C,
  • motor ambient temperature from -20°C to 40°C.

Motor

  • asynchronous, three-phase 230/400V 50Hz, 400/690V 50Hz,
    degree of protection IP 55,
    insulation class F,
    for frequency control (three-phase motors).

Special versions

  • explosion-proof design.

Technical assistance

Choose a fan www.fanselectoronline.com

m3/h
Pa
Type airflow max pressure max power max Rotation speed current max voltage Sound power
level*
temp.
min
temp.
max
weight
  m3/h Pa W rpm A V db(A) oC oC kg
HFD-2-110-17D II 2G Ex h IIB H2 T4 Gb 460 480 180 2850 0.5 400 64 40 9

HFD-2-110-17D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 460 m3/h
  • Maximum pressure 480 Pa
  • Rotation speed 2850 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 180 W
  • Rated current 0.5 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 110 mm
  • Weight 9 kg
  • Motor type AC
  • Speed number 2
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 64 dB(A)
  • Distance 1 m
HFD-4-110-17D II 2G Ex h IIB H2 T4 Gb 220 110 120 1360 0.45 400 45 40 9

HFD-4-110-17D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 220 m3/h
  • Maximum pressure 110 Pa
  • Rotation speed 1360 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 120 W
  • Rated current 0.45 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 110 mm
  • Weight 9 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 45 dB(A)
  • Distance 1 m
HFD-2-160-17D II 2G Ex h IIB H2 T4 Gb 1400 880 550 2860 1.35 400 71 40 15

HFD-2-160-17D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 1400 m3/h
  • Maximum pressure 880 Pa
  • Rotation speed 2860 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 550 W
  • Rated current 1.35 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 160 mm
  • Weight 15 kg
  • Motor type AC
  • Speed number 2
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 71 dB(A)
  • Distance 1 m
HFD-4-160-17D II 2G Ex h IIB H2 T4 Gb 700 215 250 1410 0.79 400 53 40 13

HFD-4-160-17D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 700 m3/h
  • Maximum pressure 215 Pa
  • Rotation speed 1410 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 250 W
  • Rated current 0.79 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 160 mm
  • Weight 13 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 53 dB(A)
  • Distance 1 m
HFD-2-200-17D II 2G Ex h IIB H2 T4 Gb 2800 1400 1500 2895 2.2 400 76 40 17

HFD-2-200-17D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 2800 m3/h
  • Maximum pressure 1400 Pa
  • Rotation speed 2895 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 1500 W
  • Rated current 2.2 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 200 mm
  • Weight 17 kg
  • Motor type AC
  • Speed number 2
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 76 dB(A)
  • Distance 1 m
HFD-4-200-17D II 2G Ex h IIB H2 T4 Gb 1300 335 250 1410 0.85 400 57 40 15

HFD-4-200-17D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 1300 m3/h
  • Maximum pressure 335 Pa
  • Rotation speed 1410 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 250 W
  • Rated current 0.85 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 200 mm
  • Weight 15 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 57 dB(A)
  • Distance 1 m
HFD-4-250-17D II 2G Ex h IIB H2 T4 Gb 2700 520 550 1420 1.7 400 62 40 35

HFD-4-250-17D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 2700 m3/h
  • Maximum pressure 520 Pa
  • Rotation speed 1420 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 550 W
  • Rated current 1.7 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 250 mm
  • Weight 35 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 62 dB(A)
  • Distance 1 m
HFD-4-315-15D II 2G Ex h IIB H2 T4 Gb 3600 745 1500 1450 3.3 400 71 40 48

HFD-4-315-15D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 3600 m3/h
  • Maximum pressure 745 Pa
  • Rotation speed 1450 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 1500 W
  • Rated current 3.3 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 315 mm
  • Weight 48 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 71 dB(A)
  • Distance 1 m
HFD-6-315-15D II 2G Ex h IIB H2 T4 Gb 2300 325 370 950 1.1 400 63 40 44

HFD-6-315-15D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 2300 m3/h
  • Maximum pressure 325 Pa
  • Rotation speed 950 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 370 W
  • Rated current 1.1 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 315 mm
  • Weight 44 kg
  • Motor type AC
  • Speed number 6
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 63 dB(A)
  • Distance 1 m
HFD-4-315-16D II 2G Ex h IIB H2 T4 Gb 5500 710 1500 1450 3.3 400 74 40 66

HFD-4-315-16D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 5500 m3/h
  • Maximum pressure 710 Pa
  • Rotation speed 1450 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 1500 W
  • Rated current 3.3 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 315 mm
  • Weight 66 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 74 dB(A)
  • Distance 1 m
HFD-6-315-16D II 2G Ex h IIB H2 T4 Gb 3500 305 370 950 1.1 400 61 40 60

HFD-6-315-16D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 3500 m3/h
  • Maximum pressure 305 Pa
  • Rotation speed 950 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 370 W
  • Rated current 1.1 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 315 mm
  • Weight 60 kg
  • Motor type AC
  • Speed number 6
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 61 dB(A)
  • Distance 1 m
HFD-4-355-16D II 2G Ex h IIB H2 T4 Gb 7000 850 2200 1450 4.6 400 76 40 84

HFD-4-355-16D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 7000 m3/h
  • Maximum pressure 850 Pa
  • Rotation speed 1450 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 2200 W
  • Rated current 4.6 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 355 mm
  • Weight 84 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 76 dB(A)
  • Distance 1 m
HFD-6-355-16D II 2G Ex h IIB H2 T4 Gb 4600 375 750 950 2 400 63 40 78

HFD-6-355-16D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 4600 m3/h
  • Maximum pressure 375 Pa
  • Rotation speed 950 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 750 W
  • Rated current 2 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 355 mm
  • Weight 78 kg
  • Motor type AC
  • Speed number 6
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 63 dB(A)
  • Distance 1 m
HFD-8-355-16D II 2G Ex h IIB H2 T4 Gb 3350 200 370 710 400 57 40

HFD-8-355-16D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 3350 m3/h
  • Maximum pressure 200 Pa
  • Rotation speed 710 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 370 W
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 355 mm
  • Motor type AC
  • Speed number 8
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 57 dB(A)
  • Distance 1 m
HFD-4-400-16D II 2G Ex h IIB H2 T4 Gb 11000 1150 5500 1430 11.1 400 79 40 148

HFD-4-400-16D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 11000 m3/h
  • Maximum pressure 1150 Pa
  • Rotation speed 1430 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 5500 W
  • Rated current 11.1 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 400 mm
  • Weight 148 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 79 dB(A)
  • Distance 1 m
HFD-6-400-16D II 2G Ex h IIB H2 T4 Gb 7000 495 1500 950 3.5 400 66 40 100

HFD-6-400-16D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 7000 m3/h
  • Maximum pressure 495 Pa
  • Rotation speed 950 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 1500 W
  • Rated current 3.5 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 400 mm
  • Weight 100 kg
  • Motor type AC
  • Speed number 6
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 66 dB(A)
  • Distance 1 m
HFD-8-400-16D II 2G Ex h IIB H2 T4 Gb 5450 280 550 710 1.7 400 60 40

HFD-8-400-16D II 2G Ex h IIB H2 T4 Gb

Nominal parameters

  • Max. volume flow 5450 m3/h
  • Maximum pressure 280 Pa
  • Rotation speed 710 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 550 W
  • Rated current 1.7 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 400 mm
  • Motor type AC
  • Speed number 8
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 60 dB(A)
  • Distance 1 m
HFD-2-110-17D II 3G Ex h IIB+H2 T4 Gc 460 480 180 2850 0.5 400 64 40 9

HFD-2-110-17D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 460 m3/h
  • Maximum pressure 480 Pa
  • Rotation speed 2850 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 180 W
  • Rated current 0.5 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 110 mm
  • Weight 9 kg
  • Motor type AC
  • Speed number 2
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 64 dB(A)
  • Distance 1 m
HFD-4-110-17D II 3G Ex h IIB+H2 T4 Gc 220 110 120 1360 0.45 400 45 40 9

HFD-4-110-17D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 220 m3/h
  • Maximum pressure 110 Pa
  • Rotation speed 1360 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 120 W
  • Rated current 0.45 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 110 mm
  • Weight 9 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 45 dB(A)
  • Distance 1 m
HFD-2-160-17D II 3G Ex h IIB+H2 T4 Gc 1400 880 550 2860 1.35 400 71 40 15

HFD-2-160-17D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 1400 m3/h
  • Maximum pressure 880 Pa
  • Rotation speed 2860 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 550 W
  • Rated current 1.35 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 160 mm
  • Weight 15 kg
  • Motor type AC
  • Speed number 2
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 71 dB(A)
  • Distance 1 m
HFD-4-160-17D II 3G Ex h IIB+H2 T4 Gc 700 215 250 1410 0.79 400 53 40 13

HFD-4-160-17D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 700 m3/h
  • Maximum pressure 215 Pa
  • Rotation speed 1410 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 250 W
  • Rated current 0.79 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 160 mm
  • Weight 13 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 53 dB(A)
  • Distance 1 m
HFD-2-200-17D II 3G Ex h IIB+H2 T4 Gc 2800 1400 1500 2895 2.2 400 76 40 17

HFD-2-200-17D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 2800 m3/h
  • Maximum pressure 1400 Pa
  • Rotation speed 2895 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 1500 W
  • Rated current 2.2 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 200 mm
  • Weight 17 kg
  • Motor type AC
  • Speed number 2
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 76 dB(A)
  • Distance 1 m
HFD-4-200-17D II 3G Ex h IIB+H2 T4 Gc 1300 335 250 1410 0.85 400 57 40 15

HFD-4-200-17D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 1300 m3/h
  • Maximum pressure 335 Pa
  • Rotation speed 1410 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 250 W
  • Rated current 0.85 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 200 mm
  • Weight 15 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 57 dB(A)
  • Distance 1 m
HFD-4-250-17D II 3G Ex h IIB+H2 T4 Gc 2700 520 550 1420 1.7 400 62 40 35

HFD-4-250-17D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 2700 m3/h
  • Maximum pressure 520 Pa
  • Rotation speed 1420 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 550 W
  • Rated current 1.7 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 250 mm
  • Weight 35 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 62 dB(A)
  • Distance 1 m
HFD-6-250-17D II 3G Ex h IIB+H2 T4 Gc 1800 230 250 940 0.75 400 52 40 32

HFD-6-250-17D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 1800 m3/h
  • Maximum pressure 230 Pa
  • Rotation speed 940 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 250 W
  • Rated current 0.75 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 250 mm
  • Weight 32 kg
  • Motor type AC
  • Speed number 6
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 52 dB(A)
  • Distance 1 m
HFD-2-250-15D II 3G Ex h IIB+H2 T4 Gc 3600 1520 1500 2895 3.15 400 82 40 24

HFD-2-250-15D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 3600 m3/h
  • Maximum pressure 1520 Pa
  • Rotation speed 2895 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 1500 W
  • Rated current 3.15 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 250 mm
  • Weight 24 kg
  • Motor type AC
  • Speed number 2
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 82 dB(A)
  • Distance 1 m
HFD-4-250-15D II 3G Ex h IIB+H2 T4 Gc 1800 360 250 1410 0.85 400 65 40 20

HFD-4-250-15D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 1800 m3/h
  • Maximum pressure 360 Pa
  • Rotation speed 1410 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 250 W
  • Rated current 0.85 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 250 mm
  • Weight 20 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 65 dB(A)
  • Distance 1 m
HFD-4-315-15D II 3G Ex h IIB+H2 T4 Gc 3600 745 1500 1450 3.3 400 71 40 48

HFD-4-315-15D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 3600 m3/h
  • Maximum pressure 745 Pa
  • Rotation speed 1450 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 1500 W
  • Rated current 3.3 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 315 mm
  • Weight 48 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 71 dB(A)
  • Distance 1 m
HFD-6-315-15D II 3G Ex h IIB+H2 T4 Gc 2300 325 370 950 1.1 400 63 40 44

HFD-6-315-15D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 2300 m3/h
  • Maximum pressure 325 Pa
  • Rotation speed 950 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 370 W
  • Rated current 1.1 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 315 mm
  • Weight 44 kg
  • Motor type AC
  • Speed number 6
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 63 dB(A)
  • Distance 1 m
HFD-4-315-16D II 3G Ex h IIB+H2 T4 Gc 5500 710 1500 1450 3.3 400 74 40 66

HFD-4-315-16D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 5500 m3/h
  • Maximum pressure 710 Pa
  • Rotation speed 1450 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 1500 W
  • Rated current 3.3 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 315 mm
  • Weight 66 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 74 dB(A)
  • Distance 1 m
HFD-6-315-16D II 3G Ex h IIB+H2 T4 Gc 3500 305 370 950 1.1 400 61 40 60

HFD-6-315-16D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 3500 m3/h
  • Maximum pressure 305 Pa
  • Rotation speed 950 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 370 W
  • Rated current 1.1 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 315 mm
  • Weight 60 kg
  • Motor type AC
  • Speed number 6
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 61 dB(A)
  • Distance 1 m
HFD-4-355-16D II 3G Ex h IIB+H2 T4 Gc 7000 850 2200 1450 4.6 400 76 40 84

HFD-4-355-16D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 7000 m3/h
  • Maximum pressure 850 Pa
  • Rotation speed 1450 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 2200 W
  • Rated current 4.6 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 355 mm
  • Weight 84 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 76 dB(A)
  • Distance 1 m
HFD-6-355-16D II 3G Ex h IIB+H2 T4 Gc 4600 375 750 950 2 400 63 40 78

HFD-6-355-16D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 4600 m3/h
  • Maximum pressure 375 Pa
  • Rotation speed 950 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 750 W
  • Rated current 2 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 355 mm
  • Weight 78 kg
  • Motor type AC
  • Speed number 6
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 63 dB(A)
  • Distance 1 m
HFD-8-355-16D II 3G Ex h IIB+H2 T4 Gc 3350 200 370 710 400 57 40

HFD-8-355-16D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 3350 m3/h
  • Maximum pressure 200 Pa
  • Rotation speed 710 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 370 W
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 355 mm
  • Motor type AC
  • Speed number 8
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 57 dB(A)
  • Distance 1 m
HFD-4-400-16D II 3G Ex h IIB+H2 T4 Gc 11000 1150 5500 1430 11.1 400 79 40 148

HFD-4-400-16D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 11000 m3/h
  • Maximum pressure 1150 Pa
  • Rotation speed 1430 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 5500 W
  • Rated current 11.1 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 400 mm
  • Weight 148 kg
  • Motor type AC
  • Speed number 4
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 79 dB(A)
  • Distance 1 m
HFD-6-400-16D II 3G Ex h IIB+H2 T4 Gc 7000 495 1500 950 3.5 400 66 40 100

HFD-6-400-16D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 7000 m3/h
  • Maximum pressure 495 Pa
  • Rotation speed 950 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 1500 W
  • Rated current 3.5 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 400 mm
  • Weight 100 kg
  • Motor type AC
  • Speed number 6
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 66 dB(A)
  • Distance 1 m
HFD-8-400-16D II 3G Ex h IIB+H2 T4 Gc 5450 280 550 710 1.7 400 60 40

HFD-8-400-16D II 3G Ex h IIB+H2 T4 Gc

Nominal parameters

  • Max. volume flow 5450 m3/h
  • Maximum pressure 280 Pa
  • Rotation speed 710 rpm
  • Phase 3
  • Rated voltage 400 V
  • Rated power 550 W
  • Rated current 1.7 A
  • Rated frequency 50 Hz
  • Max. allowed frequency 50 Hz
  • Min. allowed frequency 25 Hz
  • Diameter 400 mm
  • Motor type AC
  • Speed number 8
  • Motor protection class IP55
  • Max. operating temperature 40 °C
  • Max. medium temperature 40 °C
  • Sound pressure level 60 dB(A)
  • Distance 1 m

* measured in distance 1m from the fan.

Work characteristics

Dimensions

Type A B X fiD ØD ØD1 ØD2
  mm mm mm mm mm mm mm
HFD-2-110-17D II 2G Ex h IIB H2 T4 Gb 416 451 8 110 150 180
HFD-4-110-17D II 2G Ex h IIB H2 T4 Gb 416 451 8 110 150 180
HFD-2-160-17D II 2G Ex h IIB H2 T4 Gb 501 554 8 160 200 235.5
HFD-4-160-17D II 2G Ex h IIB H2 T4 Gb 501 554 8 160 200 235.5
HFD-2-200-17D II 2G Ex h IIB H2 T4 Gb 578 632 8 200 240 275
HFD-4-200-17D II 2G Ex h IIB H2 T4 Gb 578 632 8 200 240 275
HFD-4-250-17D II 2G Ex h IIB H2 T4 Gb 722 719 12 250 290 330
HFD-4-315-15D II 2G Ex h IIB H2 T4 Gb 815 740 12 315 350 400
HFD-6-315-15D II 2G Ex h IIB H2 T4 Gb 815 740 12 315 350 400
HFD-4-315-16D II 2G Ex h IIB H2 T4 Gb 800 928 12 315 365 416
HFD-6-315-16D II 2G Ex h IIB H2 T4 Gb 800 928 12 315 365 416
HFD-4-355-16D II 2G Ex h IIB H2 T4 Gb 905 1021 12 355 405 466
HFD-6-355-16D II 2G Ex h IIB H2 T4 Gb 905 1021 12 355 405 466
HFD-8-355-16D II 2G Ex h IIB H2 T4 Gb 905 1021 12 355 405 466
HFD-4-400-16D II 2G Ex h IIB H2 T4 Gb 1020 1138 16 400 450 550
HFD-6-400-16D II 2G Ex h IIB H2 T4 Gb 1020 1138 16 400 450 550
HFD-8-400-16D II 2G Ex h IIB H2 T4 Gb 1020 1138 16 400 450 550
HFD-2-110-17D II 3G Ex h IIB+H2 T4 Gc 416 451 8 110 150 180
HFD-4-110-17D II 3G Ex h IIB+H2 T4 Gc 416 451 8 110 150 180
HFD-2-160-17D II 3G Ex h IIB+H2 T4 Gc 501 554 8 160 200 235.5
HFD-4-160-17D II 3G Ex h IIB+H2 T4 Gc 501 554 8 160 200 235.5
HFD-2-200-17D II 3G Ex h IIB+H2 T4 Gc 578 632 8 200 240 275
HFD-4-200-17D II 3G Ex h IIB+H2 T4 Gc 578 632 8 200 240 275
HFD-4-250-17D II 3G Ex h IIB+H2 T4 Gc 722 719 12 250 290 330
HFD-6-250-17D II 3G Ex h IIB+H2 T4 Gc 722 719 12 250 290 330
HFD-2-250-15D II 3G Ex h IIB+H2 T4 Gc 626 614 8 250 290 327
HFD-4-250-15D II 3G Ex h IIB+H2 T4 Gc 626 614 12 250 290 327
HFD-4-315-15D II 3G Ex h IIB+H2 T4 Gc 815 740 12 315 350 400
HFD-6-315-15D II 3G Ex h IIB+H2 T4 Gc 815 740 12 315 350 400
Type A B X fiD ØD ØD1 ØD2
  mm mm mm mm mm mm mm
HFD-4-315-16D II 3G Ex h IIB+H2 T4 Gc 800 928 12 315 365 416
HFD-6-315-16D II 3G Ex h IIB+H2 T4 Gc 800 928 12 315 365 416
HFD-4-355-16D II 3G Ex h IIB+H2 T4 Gc 905 1021 12 355 405 466
HFD-6-355-16D II 3G Ex h IIB+H2 T4 Gc 905 1021 12 355 405 466
HFD-8-355-16D II 3G Ex h IIB+H2 T4 Gc 905 1021 12 355 405 466
HFD-4-400-16D II 3G Ex h IIB+H2 T4 Gc 1020 1138 16 400 450 550
HFD-6-400-16D II 3G Ex h IIB+H2 T4 Gc 1020 1138 16 400 450 550
HFD-8-400-16D II 3G Ex h IIB+H2 T4 Gc 1020 1138 16 400 450 550

Additional equipment


Venture Industries Group